S type load cell
Place of Origin: |
Zhejiang, China (Mainland) |
Product Detail
635A Load Cell, 50kg...10,000kg
Special features :
● Equivalent to OIML R60 C3 (Emax≥300kg)
regulations up to 5 000d
|
635A Load Cell, 50kg...10,000kg |
Special features : |
|
● Equivalent to OIML R60 C3 (Emax≥300kg)
regulations up to 5 000d for scales class lll
● Suitable for use under conditions of tension and
compression
● Protection to IP66/IP67
● Compatible with other sources
● Explosion proof version (Ex ib II CT4)
● Available Options:
-Service temperature range up to 120℃ [248℉]
-6-wire ciruit
-Stainless steel
|
|
|
Dimensions (in mm; 1mm = 0.03937 inches)
|
|
Technical Data |
Type |
635A |
Accuracy class according to OIML R60
Maximal numbers of load cell verification intervals (nLC)
|
-
5 000 |
C3
5 000 |
Maximal capacity (Emax)
Weight (G), approx.
|
kg
kg |
50;100;
1.3 |
300;500;1,000;
SE-2,000
0.8 |
2,000;
3,000;
5,000
1.5 |
10,000
7.5 |
Minimum load cell verification interval (Vmin)
Sensitivity (Cn)
Zero balance
Temperature effect on sensitivity (TKc) *
Temperature effect on zero balance (TKo)
Non-linearity (dlin) *
Repeatability (drep) *
Hysteresis error (dhy) *
Creep (dDR)in 30 min.
Input resistance (RLC)〔Red(+)-black(-)〕
Output resistance (Ro) 〔Green(+)-while(-)〕
Reference excitation voltage (Uref)
Maximal excitation voltage
Insulation resistance (Ris)
Nominal temperature range
Service temperature range
Storage temperature range
|
% of Cn
mV/V
mV/V
% of Cn/k
% of Cn/k
%
%
%
%
Ω
Ω
V(DC/AC)
V(DC/AC)
GΩ
℃[oF]
℃[oF]
℃[oF]
|
0.02
2±1%
±0.04
< ±0.0012
<±0.0040
<±0.017
<±0.017
< ±0.017
< ±0.023
400 ±25
350±3
0.5…12
18
>2[50 VDC ]
-10…+40[15…+105]
-25…+70[-15…+160]
-50…+85[-60…+185]
|
Safe load limit (EL)
Breaking load (Ed)
|
% of Cn
% of Cn
|
150
300
|
Protection class (IP) acc. to IEC529
|
IP66/IP67 |
Material
|
Steel alloy |
Optionally
|
Explosion proof version(Ex ib II CT4) |
|
* The data for deviation of linearity, repeatability, hysteresis error and temperature effect on sensitivity are typical values. The sum of these data meets the requirements according to OIML R60. |